Laser Particle Size Analyzers
Inquiry NowProduct Description
M-Kube supplies advanced Laser Particle Size Analyzers to laboratories and manufacturers across India, designed for accurate and repeatable particle size distribution analysis in pharmaceutical, chemical, cement, ceramics, mineral, food, agro-chemical, paint and coating, battery-material and research applications. Using laser scattering and diffraction technology, these systems characterize powders, suspensions, emulsions and slurries over a very broad measurement range, helping Indian QC laboratories, R&D centres and production plants control product quality and process consistency.
Whether you are searching for a laser particle analyzer, a particle size analyzer for routine quality control, or a laser particle size analyzer supplier in India who can recommend the right configuration for your material, M-Kube can help you select the right instrument based on your sample type, particle-size range and dispersion method.
Our range includes advanced Laser Particle Sizers, Laser Diffraction Analyzers, and integrated wet and dry dispersion systems for reliable laser particle size measurement and efficient sample analysis.
The laser diffraction particle size analyzer can measure particle size distributions from sub-micron particles through to larger micron-scale materials. With wet measurement from 0.01–3500 μm and dry measurement from 0.1–3000 μm, the system suits laboratories and QC environments working with a wide range of materials.
These laser particle size analyzer instruments use Mie scattering and/or Fraunhofer diffraction principles, depending on the measurement conditions and particle-size characteristics. The resulting data gives characteristic particle sizes such as D10, D50 and D90, together with the complete particle-size distribution – the key parameters used in laser diffraction particle size analysis.
What Is Laser Particle Size Analysis?
Laser particle size analysis measures the size distribution of particles by studying how they scatter a laser beam. Small particles scatter light at wide angles and large particles scatter at narrow angles. A detector array records the scattering pattern, and optical models (Mie theory or Fraunhofer approximation) convert it into a particle-size distribution. Laser diffraction is one of the most widely used techniques for particle sizing because it is fast, repeatable, requires little sample and covers a very wide size range in a single measurement.
These particle analyzers are available in several configurations:
Wet Dispersion: Designed for materials that can be dispersed in a liquid medium.
Typical samples include minerals and ores, ceramics, cement and construction materials, pigments, chemicals, pharmaceutical powders, food ingredients, suspensions, emulsions, fine powders and slurries. M-Kube wet systems incorporate mechanical stirring, ultrasonic dispersion and liquid circulation to improve sample dispersion before and during measurement.
Dry Dispersion: Designed for powders that are preferably measured without liquid dispersion. Dry analysis is particularly useful for powders, minerals, cement, fly ash, ceramics, battery materials, magnetic materials, chemical powders, pharmaceutical powders, agricultural products and other dry particulate materials. M-Kube dry systems use controlled air-assisted/turbulent dispersion, with automatic sample feeding available on selected configurations.
Wet & Dry Analysis: For laboratories that handle a wide variety of materials, a combined wet-and-dry system provides greater flexibility. A single analyzer can be configured with interchangeable or integrated wet and dry dispersion modules, so the laboratory can choose the appropriate method for each sample. Our Model 2309A, for example, combines a wet module covering 0.01–3500 µm with a dry module covering 0.1–3000 µm.
Nano Particle Size Analyzer and Particle Size and Shape Analyzer – Choosing the Right Technique
Many Indian laboratories ask whether a laser analyzer can also act as a nano particle size analyzer or a particle size and shape analyzer. The short answer depends on your sample:
- Sub-micron and fine particles: Selected M-Kube wet laser diffraction systems have a lower measurement limit of 0.01 µm (10 nm), so they can characterize fine and sub-micron particle populations in suspension. The result depends on the material, dispersion condition and optical properties (refractive index) of the particles.
- Very fine nanoparticle work: For narrow nanoparticle samples where measurement in the tens-of-nanometres range is the primary requirement, techniques such as dynamic light scattering (DLS) are commonly used alongside or instead of laser diffraction. Our team can advise which approach fits your sample.
- Particle shape: Laser diffraction reports an equivalent-sphere size distribution and does not measure shape directly. If shape parameters such as aspect ratio or circularity matter for your product, image-based particle analysis is the complementary technique, and laser diffraction is still the fastest way to obtain the size distribution.
Tell us your material and the information you need (size only, size and shape, or nano-range), and we will help you choose the correct approach before you invest.
Key Features
- Advanced Laser Particle Sizer technology for particle size distribution analysis
- Integrated wet and dry dispersion capabilities
- Fastest reported test speed of approximately 10 seconds
- High-speed data acquisition with sampling frequency up to 10 kHz
- Automatic optical path alignment for consistent measurement performance
- High-sensitivity, high-resolution photoelectric detection system
- Main laser with 639 nm wavelength and auxiliary blue laser at 405 nm
- 116 measurement channels
- Automated wet sample dispersion using ultrasonic treatment, mechanical stirring and circulation
- Dry sample analysis using turbulent dispersion and automatic sample introduction
- Adjustable ultrasonic dispersion at 40 kHz and 60 W
- Adjustable stirring speed from 0–3000 rpm
- Built-in wet circulation system with adjustable flow
- SOP-based fully automated operation, which supports consistent results across operators and shifts
- Automatic water intake, bubble removal, dispersion, measurement, cleaning and data processing for wet analysis
- Automatic dust collection, air supply, feeding, testing and data processing for dry analysis
- Statistical comparison of multiple test results
- Customisable particle size distribution analysis
- Data and test reports can be exported in Word, Excel, PDF, image and text formats
- English-language interface
- GMP option available for suitable applications
Available Configurations
Rather than selecting a model purely by model number, the appropriate laser particle size analyzer can be chosen according to the sample type, particle-size range and dispersion method.
| Requirement | Recommended configuration |
|---|---|
| Fine particles in liquid | Wet laser particle size analyzer |
| Dry powder | Dry laser particle size analyzer |
| Laboratory testing of both powders and suspensions | Wet + dry analyzer |
| Very broad particle-size distribution | Large-range laser particle size analyzer |
| Routine QC testing | Automated wet or dry analyzer |
| Research & development | Modular, flexible wet/dry configuration |
| High repeatability / standardized testing | Fully automated system with SOP operation |
| Very fine / sub-micron measurement | Suitable wet configuration with extended lower range |
| Large particle-size range | Large-range wet/dry configuration |
M-Kube Laser Particle Size Analyzer Models Available in India
M-Kube’s portfolio includes multiple models and configurations. Rather than presenting each variant as a separate product, the range can be broadly understood as follows:
| Product family | Configuration | Published / indicative range* | Primary use |
|---|---|---|---|
| Model 2309A | Modular Wet + Dry | Wet: 0.01–3500 µm; Dry: 0.1–3000 µm | Research, R&D and advanced QC |
| Model 2309A Module-201 | Wet | 0.01–3500 µm | Large-range wet analysis |
| Model 2309A Module-301 | Dry | 0.1–3000 µm | Large-range dry analysis |
| Model 2309B | Modular Wet + Dry | Configuration dependent | Laboratory / QC |
| Model 2309C | Modular Wet + Dry | Configuration dependent | Laboratory / QC |
| Model 2308A | Integrated Wet + Dry | Wet: 0.01–2000 µm; Dry: 0.1–2000 µm | Automated laboratory analysis |
| Model 2308B | Integrated Wet + Dry | Wet: 0.01–1200 µm; Dry: up to 1200 µm | Laboratory / QC |
| Model 2008A/B | Automatic Wet | Up to approx. 1200–2000 µm depending on model | Routine wet analysis |
| Model 2006A | Intelligent Wet | 0.01–1000 µm | Wet laboratory analysis |
| Model 3008A/B | Dry | Model dependent | Dry powder analysis |
| Model 3006 / 3003 | Dry | Model dependent | Routine dry analysis |
| Model 2018 | Automatic Wet | Model dependent | Routine wet analysis |
*Measurement ranges and configurations vary by model. M-Kube can recommend the appropriate configuration based on your material, expected particle-size range and dispersion requirements.
Typical Technical Specifications
| Specification | Model 2309A |
|---|---|
| Measurement Principle | Mie and Fraunhofer scattering |
| Measurement Range – Wet | 0.01–3500 μm |
| Measurement Range – Dry | 0.1–3000 μm |
| Number of Channels | 116 |
| Accuracy Error | Wet: ≤0.5%; Dry: ≤1.0% (CRM D50) |
| Repeatability Error | Wet: ≤0.5%; Dry: ≤1.0% (CRM D50) |
| Test Speed | Fastest 10 seconds |
| Sampling Frequency | Up to 10 kHz |
| Light Source – Main Laser | High-performance laser, λ=639 nm, P>2 mW |
| Light Source – Auxiliary Laser | Blue laser, λ=405 nm, P>2 mW |
| Optical Path | Reverse Fourier (folded optical path) |
| Optical Bench Alignment | Automatic alignment |
| Laser Safety | Class 1 |
| Wet Dispersion | Ultrasonic, mechanical stirring and built-in circulating dispersion |
| Ultrasonic Dispersion | 40 kHz, 60 W; time adjustable |
| Stirring Speed | 0–3000 rpm, adjustable |
| Circulation Flow Rate | 1–8 L/min |
| Circulation Power | 120 W |
| Dry Dispersion | Turbulent dispersion with automatic sample introduction |
| Sample Tank Volume | 600 mL |
| Wet Sample Injector | WinModule-201 |
| Dry Sample Injector | WinModule-301 |
| Operation Mode | SOP fully automated operation |
| Refractive Index | Wide range; user-defined refractive index can be entered |
| Outer Dimensions – Main Unit | 870 × 340 × 380 mm |
| Outer Dimensions – Wet Module | 415 × 280 × 335 mm |
| Outer Dimensions – Dry Module | 260 × 245 × 295 mm |
| Net Weight – Main Unit | 32 kg |
| Net Weight – Wet Module | 15 kg |
| Net Weight – Dry Module | 7 kg |
| Analysis Patterns | Free distribution, R-R distribution, log-normal distribution and statistical models |
| Data Output | Particle size values, differential distribution data/graphs and cumulative distribution data/curves |
| Test Report Formats | Word, Excel, BMP, TXT and PDF |
| Language | English and Chinese; other languages available on request |
| GMP | Optional |
The specifications above are based on the referenced product information. Actual configuration and supplied accessories (including power supply requirements for your site in India) should be confirmed according to the selected system and application requirements.
Applications of Laser Particle Size Analyzers in India
M-Kube’s laser particle size analyzers are used for particle-size characterization across the industries that drive India’s manufacturing and research base:
- Pharmaceutical & Medical Materials: Pharmaceutical powders, excipients, active pharmaceutical ingredients (APIs), pharmaceutical coatings, suspensions, formulation materials, and in-process and quality-control testing for pharma units and contract manufacturers.
- Chemical & Powder Materials: Chemical powders, catalysts, fillers, pigments, industrial and speciality chemicals, agrochemical formulations and functional materials.
- Food & Agriculture: Flour, starch, spices and food powders, agricultural products, fertilizers and other particulate food and agricultural materials.
- Cement & Construction Materials: Cement, fly ash, slag, limestone, construction powders and fine aggregates – where fineness and particle-size distribution directly affect strength and performance.
- Ceramics & Advanced Materials: Ceramic powders, alumina, zirconia, silicon carbide, electronic ceramics, refractory materials, tile and sanitaryware raw materials, and advanced ceramic powders.
- Paints, Coatings & Pigments: Intermediates, pigment powders, pigment emulsions, textile emulsions and acrylic emulsions.
- Mining, Minerals & Metallurgy: Ores, mineral powders, geological materials, slurries, industrial minerals and processed mineral products.
- Battery & Electronic Materials: Cathode materials, anode materials, battery powders, conductive materials and mineral-based energy materials, supporting India’s growing battery and energy-storage sector.
- Research & Academia: The broad configuration range makes these systems suitable for universities, research institutes, national laboratories and corporate R&D centres where different materials and measurement conditions need to be evaluated.
Why Choose M-Kube in India
- Reliable laser particle size analyzer supplier serving customers across India
- Advanced laser diffraction technology for particle size distribution analysis
- Wet, dry and integrated wet/dry configurations available
- Broad measurement range for fine and larger micron-scale particles
- Suitable for research, laboratory, industrial and quality-control applications
- Automated sample dispersion and testing functions
- High-resolution optical detection and automatic optical alignment
- Flexible data analysis and statistical comparison functions
- Suitable for powders, suspensions, emulsions and other particulate materials
- Technical assistance in selecting the appropriate configuration for your application
- Solutions for pharmaceutical, chemical, food, mineral, ceramic, battery, coating, cement and advanced-material applications
- Customised configurations and language options may be available according to requirements
- Installation, application training and after-sales support.
All M-Kube analytical equipment is manufactured in ISO-certified facilities and tested in accordance with relevant ASTM standards. This ensures each instrument meets global benchmarks for quality, consistency, accuracy and reliable analytical performance.
Buy Laser Particle Size Analyzer in India – Request a Quote
Looking for a laser particle size analyzer in India, a Laser Particle Sizer, a Laser Diffraction Analyzer, or a dependable laser particle analyzer India supplier? Tell us what material you need to analyze, its approximate particle-size range and whether it is handled wet or dry. We will help you identify the appropriate configuration and provide a quotation.
Contact M-Kube Enterprise
📞 Call +91 9898892994
📧 Email marketing@mkubeenterprise.co.in
Contact us today for product pricing, technical specifications, available configurations, application suitability, and assistance in selecting the right laser scattering particle size analyzer for your requirements.
Product FAQ's
What is a laser particle size analyzer?
A laser particle size analyzer measures the particle-size distribution of a material by analyzing the way particles scatter laser light. It is also called a laser diffraction particle size analyzer or laser particle analyzer.
What is the difference between wet and dry particle-size analysis?
Wet analysis disperses particles in a liquid medium before measurement, while dry analysis uses air-assisted dispersion. The appropriate method depends on the material and the required test procedure.
What particle-size range can these analyzers measure?
M-Kube offers several configurations with different measurement ranges. The 2309A, for example, is specified for 0.01–3500 µm in wet mode and 0.1–3000 µm in dry mode. Other models provide narrower ranges for specific laboratory requirements.
Can one analyzer perform both wet and dry measurements?
Yes. M-Kube offers integrated and modular wet-and-dry systems. The 2309A and 2308 series are examples of systems designed for both dispersion methods.
Can particle size below 1 µm be measured?
Yes. Selected M-Kube wet laser diffraction systems have published lower measurement limits of 0.01 µm. The appropriate configuration depends on the material, dispersion condition and optical properties of the particles. For work focused only on very fine nanoparticles, ask our team whether laser diffraction or another technique suits your sample best.
Can a laser particle size analyzer measure particle shape?
Laser diffraction reports particle size distribution based on an equivalent-sphere model and does not measure shape directly. Where shape information such as aspect ratio is needed, image-based analysis is typically used as a complementary technique.
What is D50?
D50 is the particle size at which 50% of the measured particle population is smaller and 50% is larger, according to the reported particle-size distribution.
What are D10 and D90?
D10 and D90 represent characteristic points on the cumulative particle-size distribution and are commonly used together with D50 to describe the distribution.
Is laser diffraction suitable for powders?
Yes. M-Kube offers dedicated dry-dispersion laser particle size analyzers as well as combined wet/dry systems for powders.
Which industries in India use laser particle size analyzers?
They are widely used in pharmaceuticals, cement and construction materials, ceramics, chemicals and pigments, paints and coatings, minerals and mining, food and agriculture, battery materials, and in university and research laboratories.
Do you supply laser particle size analyzers across India?
Yes. M-Kube supplies to customers across India [confirm delivery, installation and training coverage]. Contact us with your location and application for availability and lead-time details.
Which particle size analyzer should I choose?
The correct analyzer depends on the expected particle-size range, material type, wet/dry handling, dispersion behaviour, required automation and application. M-Kube can help select the appropriate configuration based on these parameters.



