Mkube Digital Automatic Polarimeter Instrument for Sugar Analysis
Digital-Automatic-Polarimeter-for-sugar-analysis

Automatic Polarimeters (P810, P850, P810 Pro, P850 Pro)

Inquiry Now

Product Description

The Automatic Polarimeters – models P810, P850, P810 Pro, and P850 Pro – are high-precision instruments designed for measuring optical rotation, concentration, specific rotation, and sugar degree. Leveraging advanced photoelectric inspection technology, these polarimeter instruments deliver fast, accurate, and repeatable results. Whether for pharmaceuticals, food and beverage, sugar, chemicals, petroleum, or research laboratories, these digital automatic polarimeters are trusted for their performance and reliability.

The P810 Pro and P850 Pro come with upgraded features, including an Android-based system, enhanced connectivity, and FDA 21 CFR Part 11 compliance, making them ideal for regulated industries.

Key Features

  • Regulatory Compliance: P810 Pro and P850 Pro models meet FDA 21 CFR Part 11 standards, ensuring data traceability, secure e-signatures, and user access control.
  • Automatic Calibration: Simplifies routine calibration, ensuring precision without requiring technical expertise.
  • Peltier Temperature Control (P850/P850 Pro): Maintains a stable temperature range of 15°C–30°C with ±0.3°C accuracy for consistent measurement results.
  • High-Brightness LED Light Source: Durable LED lamp with a lifespan of over 100,000 hours, eliminating frequent replacements.
  • User-Friendly Touchscreen: 5.6-inch display (P810/P850) and upgraded 8-inch Android touchscreen (Pro models) for intuitive operation.
  • Flexible Connectivity: USB, RS232, and Wi-Fi (Pro models) for easy data transfer, printer connection, and PC backup.
  • Data Storage: Capacity for 1000 records (P810) and up to 8GB storage (P850, P810 Pro, P850 Pro) for results, methods, and audit trails.
  • Multilingual Support (Pro Models): Available in English, Chinese, and Russian.
  • Sample Compatibility: Accepts tubes up to 200 mm, including corrosion-resistant and micro sample tubes.

 

Technical Specifications

 

Specification P810 P850 P810 Pro P850 Pro
Measuring range ± 89.99°Arc; ± 259°Z ± 89.99°Arc; ± 259°Z ± 89.99°Arc; ± 259°Z ± 89.99°Arc; ± 259°Z
Measuring Model Optical Rotation; Specific Rotation; Concentration; Sugar Degree Optical Rotation; Specific Rotation; Concentration; Sugar Degree Optical Rotation; Specific Rotation; Concentration; Sugar Degree Optical Rotation; Specific Rotation; Concentration; Sugar Degree
Min. reading 0.001°(optical rotation) 0.001°(optical rotation) 0.001°(optical rotation) 0.001°(optical rotation)
Accuracy ±0.01º (-45º≤ optical rotation ≤ +45º);

±0.02º ( optical rotation˂ – 45º or optical rotation > +45º)

±0.01º (-45º≤ optical rotation ≤ +45º);

±0.02º ( optical rotation˂ – 45º or optical rotation > +45º)

±0.01º (-45º≤ optical rotation ≤ +45º);

±0.02º ( optical rotation˂ – 45º or optical rotation > +45º)

±0.01º (-45º≤ optical rotation ≤ +45º);

±0.02º ( optical rotation˂ – 45º or optical rotation > +45º)

Repeatability (standard deviation) 0.002°(optical rotation) 0.002°(optical rotation) 0.002°(optical rotation) 0.002°(optical rotation)
Light Source LED LED LED LED
Wavelength 589.3 nm 589.3 nm 589.3 nm 589.3 nm
Temperature Control No Peltier No Peltier
Temperature Control Range 15℃30℃ 15℃30℃ 15℃30℃ 15℃30℃
Temperature Control Accuracy 0.3℃ 0.3℃ 0.3℃ 0.3℃
Temperature resolution 0.1℃ 0.1℃ 0.1℃ 0.1℃
Communication Port USB; RS232 USB×3,RS232Wi-Fi USB×3,RS232Wi-Fi USB×3,RS232Wi-Fi
Data Storable 1000 8GB 8GB 8GB
21CFR Part 11 No                 No Yes Yes
Tamper-proof data output No Yes Yes Yes
Display 5.6 inch                                         

                                           8 inch

Sample Cell Upto 200 mm Upto 200 mm Upto 200 mm Upto 200 mm
Graphic No                    

 4 hours

        

 4 hours

    

 4 hours

Power 220V AC (±10%) 50 Hz 220V AC (±10%) 50 Hz 220V AC (±10%) 50 Hz 220V AC (±10%) 50 Hz
Calibration (rotation value) Optional Optional Optional Optional
Optional Parts Sample tubes, including corrosion-resistant tubes or micro tubes Sample tubes, including corrosion-resistant tubes or micro tubes Sample tubes, including corrosion-resistant tubes or micro tubes Sample tubes, including corrosion-resistant tubes or micro tubes

 

Applications

  • Pharmaceutical Industry: Ensures drug purity and consistency by analyzing optical rotation of active pharmaceutical ingredients (APIs).
  • Food & Beverage: Determines sugar content, flavors, and additives for quality control.
  • Sugar Industry: Measures sugar concentration and degree of purity with high precision.
  • Petroleum & Chemicals: Used for verifying chemical compound purity and monitoring refining processes.
  • Research & Education: Suitable for laboratories and universities studying molecular optical properties.
  • Flavors & Spices: Maintains consistency of essential oils and flavor extracts in production.

 

Quality and Compliance

At M-Kube, all niobium sheets, plates, and foils are produced in ISO-certified facilities, meeting ASTM, ISO, and international standards. We ensure strict quality control so each product delivers purity, durability, and precision performance

 

Why Choose M-Kube for Automatic Polarimeters?

At M-Kube, we go beyond supplying laboratory instruments—we provide reliable solutions that meet the highest industry standards. When you choose M-Kube for your Automatic Polarimeter needs, you benefit from:

  • Trusted Global Partnerships – We work with leading manufacturers to deliver polarimeters that combine innovation, compliance, and durability.
  • Industry Expertise – Our team understands the demands of pharmaceuticals, sugar, food & beverage, and research sectors, ensuring we recommend the right model for your application.
  • Regulatory Compliance – With options like the P810 Pro and P850 Pro, we provide FDA 21 CFR Part 11-compliant solutions ideal for regulated environments.
  • Technical Support & Service – From installation to troubleshooting, our support team ensures smooth operations and minimal downtime.
  • Competitive Pricing – Get high-performance polarimeters at a price that balances quality and value.

With M-Kube, you’re not just purchasing an instrument—you’re investing in a long-term partnership for precision and reliability.

Get a Quote

Looking for the right Automatic Polarimeter for your lab or production facility? Whether you need the P810, P850, P810 Pro, or P850 Pro, M-Kube can help you choose the model that best fits your requirements.

📞 Call: +91-9898892994
📧 Email: marketing@mkubeenterprise.co.in 

Our experts will provide a personalized quote, technical guidance, and delivery options tailored to your needs.

Product FAQ's

What is the measurement range of the Auto Digital Polarimeter?

The Auto Digital Polarimeter typically offers a measurement range of ±45° for optical rotation and up to ±120°Z for sugar degrees, suitable for various applications.

What is the accuracy of the Auto Digital Polarimeter?

The accuracy varies depending on the model, but many offer an optical rotation accuracy of ±0.01° and a repeatability of 0.002°, ensuring precise measurements.

What light source is used in the Auto Digital Polarimeter?

Most Auto Digital Polarimeters utilize LED light sources, commonly at a wavelength of 589.3 nm, providing stable and consistent illumination for measurements.

How is temperature controlled in the Auto Digital Polarimeter?

Many models feature Peltier temperature control systems, allowing for precise temperature regulation within a range of 10°C to 55°C, with a resolution of 0.1°C.

What type of display does the Auto Digital Polarimeter have?

The instrument is equipped with a color touch screen, typically around 8 inches, facilitating easy operation and data visualization.

Is the Auto Digital Polarimeter suitable for sugar analysis?

Yes, the Auto Digital Polarimeter is designed to measure sugar degrees (°Z), making it ideal for sugar analysis in various industries.

What is the minimum sample transmittance required for accurate measurements?

Accurate measurements are typically achievable with a minimum sample transmittance of 1%, ensuring reliable results.

Does the Auto Digital Polarimeter come with data output capabilities?

Yes, many models are equipped with RS232 interfaces, allowing for easy data transfer and integration with other systems.

Is an automatic polarimeter different from a digital polarimeter?

Yes, automatic polarimeter and digital polarimeter terms are often used interchangeably depending on model type.