Fluorescence & Self-Masking Cuvettes
Inquiry NowProduct Description
M-Kube Enterprise offers premium-quality Fluorescence & Self-Masking Cuvettes engineered for highly sensitive fluorescence measurements and advanced spectrofluorometric analysis. Manufactured from high-purity optical quartz, our Fluorescence Spectroscopy Cuvette range provides exceptional UV-Visible transmission, extremely low background fluorescence, and excellent chemical resistance, ensuring accurate and reproducible analytical results.
Our comprehensive range includes fluorescence quartz cuvette, Black Wall Fluorescence Cuvette, Self-Masking Quartz Cuvette, Self-Masking Cell, Self-Masking Flow-Through Cell, and UV Quartz Fluorescence Cells, making them ideal for pharmaceutical research, biotechnology, environmental testing, chemical analysis, and academic laboratories across India.
Designed to minimise stray light and maximise fluorescence signal detection, M-Kube Enterprise Fluorescence Cuvettes And Cells are compatible with most fluorometers, spectrofluorometers, and fluorescence spectroscopy systems.
Key Features
- Manufactured from premium optical quartz for exceptional UV-Visible transmission
- Specifically designed for fluorescence spectroscopy and spectrofluorometric analysis
- Ultra-low background fluorescence for enhanced measurement sensitivity
- Black Wall Fluorescence Cuvette design minimises stray light and optical interference
- Available as Self-Masking Quartz Cuvette and Self-Masking Flow-Through Cell configurations
- Excellent resistance to chemicals, solvents, and laboratory reagents
- Precision-polished optical windows for superior optical performance
- Compatible with most fluorometers and spectrofluorometers
- PTFE stopper options available for volatile and sensitive samples
- Durable, reusable, and easy-to-clean construction
- Available in multiple path lengths and sample volume capacities
- Custom designs and specialised configurations available on request
Typical Technical Specifications
| Material | Code | Transmission on Empty Cell | Deviations in Matching |
| Optical Glass | G | At 350nm approx. 82% | At 350nm max. 0.5% |
| UV Quartz Glass | H | At 220nm approx. 80% | At 220nm max. 0.5% |
| ES Quartz Glass | Q | At 200nm approx. 80% | At 200nm max. 0.5% |
| IR Quartz Glass | I | At 2730nm approx. 88% | At 2730nm max. 0.5% |
| Product Name | OutsideDimensions
H x W x D |
Path Lengthmm | Inside Width mm | Volumeml | Product number | ||
| Es Quartz Glass
19nm-2500nm |
IR Quartz Glass
250nm -3500nm |
Optical Glass 340nm-2500nm | |||||
| Self-masking continuous flow through cell | 45×12.5×7.5 – 45×12.5×12.5 | 5 – 10 | Ø3 – Ø1.5 | 0.035 – 0.018 | Q-63 – Q-70 | I-63 – I-70 | G-63 – G-70 |
| Self-masking continuous flow through cell | 45×12.5×7.5 – 45×12.5×12.5 | 5 – 10 | 4×12 – 2×12 | 0.24 – 0.24 | Q-73 – Q-80 | I-73 – I-80 | G-73 – G-80 |
| Self-masking continuous flow through cell | 45×12.5×7.5 – 45×12.5×32.5 | 10 – 30 | Ø1 – Ø2 | 0.01 – 0.09 | Q-154 – Q-176 | I-154 – I-176 | G-154 – G-176 |
| Self-masking continuous flow through cell | 15×12.4×12.4 | 10 | Ø2 | 0.03 | Q-604 | I-604 | G-604 |
| Self-masking continuous flow through cell | 35×12.4×12.4 | 10 | Ø2 | 0.03 | Q-614 | I-614 | G-614 |
| Self-masking continuous flow through cell | 34×12.5×12.5 | 10 | Ø2 | 0.03 | Q-624 | I-624 | G-624 |
Applications
Fluorescence Spectroscopy
Our Fluorescence Spectroscopy Cuvette range is specifically designed for highly sensitive fluorescence measurements with minimal background interference, making it ideal for both qualitative and quantitative fluorescence analysis.
Spectrofluorometric Analysis
These fluorescence quartz cuvette solutions provide exceptional optical precision for fluorescence excitation and emission studies in pharmaceutical, biotechnology, chemical, and research laboratories.
Pharmaceutical & Biotechnology Research
Ideal for protein analysis, DNA/RNA quantification, enzyme kinetics, fluorescence-labelled assays, biomolecular interaction studies, drug discovery, and life science research.
Environmental & Chemical Analysis
Suitable for trace contaminant detection, water quality monitoring, fluorescence-based chemical testing, environmental analysis, and industrial laboratory applications.
Continuous Flow Measurements
Our Self-Masking Flow-Through Cell range enables continuous sample analysis for automated analytical systems, online process monitoring, and high-throughput fluorescence measurements.
Research & Academic Laboratories
Widely used in universities, research institutes, government laboratories, and industrial R&D facilities for fluorescence spectroscopy, photoluminescence studies, nanotechnology, and advanced analytical research.
Why Choose M-Kube Enterprise?
- Trusted supplier of Fluorescence & Self-Masking Cuvettes in India
- Premium-quality UV Quartz Fluorescence Cells manufactured from high-purity optical quartz
- Comprehensive range including Black Wall Fluorescence Cuvette, Self-Masking Quartz Cuvette, and Self-Masking Flow-Through Cell
- Precision optical manufacturing for highly accurate fluorescence measurements
- Self Masking Black Walls effectively reduce stray light for enhanced signal detection
- Compatible with most fluorometers and spectrofluorometers
- Custom path lengths, sample volumes, and specialised configurations available
- Competitive pricing with consistent product quality
- Technical support for fluorescence spectroscopy and advanced analytical applications
- Reliable nationwide supply for pharmaceutical, biotechnology, environmental, research, and industrial laboratories
All M-Kube Enterprise Fluorescence Cuvettes And Cells are manufactured in ISO-certified facilities using premium optical quartz and stringent quality control procedures. Every Self-Masking Cell undergoes rigorous inspection for optical transmission, dimensional accuracy, and surface quality to ensure dependable fluorescence measurements and long-term laboratory performance.
Buy Fluorescence & Self-Masking Cuvettes in India – Request a Quote
Looking for Fluorescence & Self-Masking Cuvettes, Fluorescence Spectroscopy Cuvette, fluorescence quartz cuvette, Black Wall Quartz Cuvette, Self-Masking Quartz Cuvette, Self-Masking Cell, Self-Masking Flow-Through Cell, or UV Quartz Fluorescence Cells?
📞 Call: +91 9898892994 OR 📧 Email: marketing@mkubeenterprise.co.in today for high-performance fluorescence cuvettes for pharmaceutical companies, biotechnology organisations, research institutes, universities, environmental laboratories, and industrial testing facilities across India.
Product FAQ's
What are the benefits of a fluorescence quartz cuvette?
A fluorescence quartz cuvette offers excellent optical transmission across suitable UV and visible wavelength ranges. It is widely used for fluorescence measurements where sample transparency and compatibility with the instrument’s optical requirements are important.
How does a self-masking quartz cuvette work?
A Self-Masking Quartz Cuvette incorporates an optical design intended to reduce unwanted light transmission through selected walls. This can help minimize interference from stray light in specific measurement configurations.
When should I use a black wall fluorescence cuvette?
A Black Wall Fluorescence Cuvette is useful for applications where reducing unwanted reflections and stray light is important. Its suitability depends on the instrument’s optical geometry and the requirements of the fluorescence measurement.
What are self-masking cuvettes designed for?
Self-masking cuvettes are designed to control unwanted light transmission through selected surfaces. They can support fluorescence analysis by helping reduce optical interference when used with compatible spectrophotometers or fluorometers.
What should I consider when selecting fluorescence cuvettes and cells?
When choosing Fluorescence Cuvettes And Cells, consider the wavelength range, material, optical path length, sample volume, and instrument configuration. These factors help ensure the cell meets your analytical requirements.
When should I choose a black wall quartz cuvette?
A Black Wall Quartz Cuvette is a suitable option when quartz optical properties and a light-reducing wall design are required. Before selecting one, verify the wavelength range, optical orientation, and compatibility with your fluorescence instrument.
Are UV quartz fluorescence cells suitable for UV measurements?
UV Quartz Fluorescence Cells are designed for applications requiring suitable ultraviolet light transmission. Confirm the quartz grade, wavelength range, and optical specifications to ensure compatibility with your testing method.








